2024-12-08 03:06:42 +00:00

113 lines
3.5 KiB
JSON

{
"id": "CVE-2018-9065",
"sourceIdentifier": "psirt@lenovo.com",
"published": "2018-07-30T16:29:00.377",
"lastModified": "2024-11-21T04:14:54.050",
"vulnStatus": "Modified",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "In Lenovo xClarity Administrator versions earlier than 2.1.0, an attacker that gains access to the underlying LXCA file system user may be able to retrieve a credential store containing the service processor user names and passwords for servers previously managed by that LXCA instance, and potentially decrypt those credentials more easily than intended."
},
{
"lang": "es",
"value": "En Lenovo xClarity Administrator en versiones anteriores a la 2.1.0, un atacante que obtiene acceso al usuario del sistema de archivos de LXCA podr\u00eda ser capaz de recuperar un almac\u00e9n de credenciales que contiene los nombres de usuario y contrase\u00f1as del procesador del servicio para los servidores gestionados previamente por la instancia LXCA y, potencialmente, descifrar estas credenciales de forma m\u00e1s sencilla de lo que parece."
}
],
"metrics": {
"cvssMetricV30": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.0",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"attackVector": "NETWORK",
"attackComplexity": "HIGH",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 1.6,
"impactScore": 5.9
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:M/Au:S/C:P/I:N/A:N",
"baseScore": 3.5,
"accessVector": "NETWORK",
"accessComplexity": "MEDIUM",
"authentication": "SINGLE",
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"availabilityImpact": "NONE"
},
"baseSeverity": "LOW",
"exploitabilityScore": 6.8,
"impactScore": 2.9,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-312"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:lenovo:xclarity_administrator:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2.1.0",
"matchCriteriaId": "3A86A91D-7F8C-44EE-B159-1F8B206B7EA9"
}
]
}
]
}
],
"references": [
{
"url": "https://support.lenovo.com/us/en/solutions/LEN-22168",
"source": "psirt@lenovo.com",
"tags": [
"Vendor Advisory"
]
},
{
"url": "https://support.lenovo.com/us/en/solutions/LEN-22168",
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
]
}
]
}