2024-12-08 03:06:42 +00:00

211 lines
6.2 KiB
JSON

{
"id": "CVE-2020-5344",
"sourceIdentifier": "security_alert@emc.com",
"published": "2020-03-31T22:15:14.760",
"lastModified": "2024-11-21T05:33:57.083",
"vulnStatus": "Modified",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Dell EMC iDRAC7, iDRAC8 and iDRAC9 versions prior to 2.65.65.65, 2.70.70.70, 4.00.00.00 contain a stack-based buffer overflow vulnerability. An unauthenticated remote attacker may exploit this vulnerability to crash the affected process or execute arbitrary code on the system by sending specially crafted input data."
},
{
"lang": "es",
"value": "Dell EMC iDRAC7, iDRAC8 e iDRAC9 versiones anteriores a 2.65.65.65, 2.70.70.70, 4.00.00.00, contienen una vulnerabilidad de desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria. Un atacante remoto no autenticado puede explotar esta vulnerabilidad para bloquear el proceso afectado o ejecutar c\u00f3digo arbitrario sobre el sistema mediante el env\u00edo de datos de entrada especialmente dise\u00f1ados."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "security_alert@emc.com",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:H",
"baseScore": 7.0,
"baseSeverity": "HIGH",
"attackVector": "NETWORK",
"attackComplexity": "HIGH",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 2.2,
"impactScore": 4.7
},
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"baseScore": 10.0,
"accessVector": "NETWORK",
"accessComplexity": "LOW",
"authentication": "NONE",
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"availabilityImpact": "COMPLETE"
},
"baseSeverity": "HIGH",
"exploitabilityScore": 10.0,
"impactScore": 10.0,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "security_alert@emc.com",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-121"
}
]
},
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-787"
}
]
}
],
"configurations": [
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:dell:idrac7_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2.65.65.65",
"matchCriteriaId": "3494B3FA-1BE5-4817-9F92-1A19F2776680"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:dell:idrac7:-:*:*:*:*:*:*:*",
"matchCriteriaId": "6B004193-6FCE-4E0C-9B3F-D56B4605701B"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:dell:idrac8_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2.70.70.70",
"matchCriteriaId": "3081DFE4-72FC-497B-946D-9B9AB9AFCC76"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:dell:idrac8:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B0591F64-CBB4-440D-AB35-F8D5AC8A536B"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:dell:idrac9_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.00.00.00",
"matchCriteriaId": "B3F9892D-A0B0-4938-9C38-C8A511860011"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:dell:idrac9:-:*:*:*:*:*:*:*",
"matchCriteriaId": "BD8B684E-092F-496C-9D94-51CCD1F3575A"
}
]
}
]
}
],
"references": [
{
"url": "https://www.dell.com/support/article/en-us/sln320717/dsa-2020-063-idrac-buffer-overflow-vulnerability?lang=en",
"source": "security_alert@emc.com",
"tags": [
"Vendor Advisory"
]
},
{
"url": "https://www.dell.com/support/article/en-us/sln320717/dsa-2020-063-idrac-buffer-overflow-vulnerability?lang=en",
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
]
}
]
}