2024-12-08 03:06:42 +00:00

201 lines
6.5 KiB
JSON

{
"id": "CVE-2020-8234",
"sourceIdentifier": "support@hackerone.com",
"published": "2020-08-21T21:15:12.027",
"lastModified": "2024-11-21T05:38:33.570",
"vulnStatus": "Modified",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability exists in The EdgeMax EdgeSwitch firmware <v1.9.1 where the EdgeSwitch legacy web interface SIDSSL cookie for admin can be guessed, enabling the attacker to obtain high privileges and get a root shell by a Command injection."
},
{
"lang": "es",
"value": "Se presenta una vulnerabilidad en The EdgeMax EdgeSwitch versiones de firmware anteriores a v1.9.1, donde puede ser adivinada la cookie SIDSSL de la interfaz web heredada de EdgeSwitch para el administrador, permitiendo al atacante obtener altos privilegios y obtener un shell root mediante una inyecci\u00f3n de Comando."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"baseScore": 10.0,
"accessVector": "NETWORK",
"accessComplexity": "LOW",
"authentication": "NONE",
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"availabilityImpact": "COMPLETE"
},
"baseSeverity": "HIGH",
"exploitabilityScore": 10.0,
"impactScore": 10.0,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "support@hackerone.com",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-613"
}
]
},
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-613"
}
]
}
],
"configurations": [
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:ui:edgemax_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "1.9.1",
"matchCriteriaId": "F9A1458F-C99F-4F7F-8D07-151492B0AED6"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:o:ui:ep-s16:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4D52DC6E-7DEA-47B0-9202-0EDEF033D09D"
},
{
"vulnerable": false,
"criteria": "cpe:2.3:o:ui:es-12f:-:*:*:*:*:*:*:*",
"matchCriteriaId": "16EDA969-F46D-4D35-8502-0BF23FF843BA"
},
{
"vulnerable": false,
"criteria": "cpe:2.3:o:ui:es-16-150w:-:*:*:*:*:*:*:*",
"matchCriteriaId": "BB3291E6-3349-4BC1-B4D9-D14D5B4F2CC2"
},
{
"vulnerable": false,
"criteria": "cpe:2.3:o:ui:es-16-xg:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DC80F08E-FE2C-4D6F-8861-410A8CB488C9"
},
{
"vulnerable": false,
"criteria": "cpe:2.3:o:ui:es-24-250w:-:*:*:*:*:*:*:*",
"matchCriteriaId": "15658C2B-DDDB-4E63-AB3B-95E1244A2985"
},
{
"vulnerable": false,
"criteria": "cpe:2.3:o:ui:es-24-500w:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F13AA35A-5F54-4332-9F5E-7216931C1FF3"
},
{
"vulnerable": false,
"criteria": "cpe:2.3:o:ui:es-24-lite:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C61D8B37-AAAA-40B3-BFDB-0D0BC476E5CB"
},
{
"vulnerable": false,
"criteria": "cpe:2.3:o:ui:es-48-500w:-:*:*:*:*:*:*:*",
"matchCriteriaId": "50F1E43E-30CF-4CAF-B6F2-E0743588865E"
},
{
"vulnerable": false,
"criteria": "cpe:2.3:o:ui:es-48-750w:-:*:*:*:*:*:*:*",
"matchCriteriaId": "00789E82-2933-4A83-95F7-D2CBCCBF4E17"
},
{
"vulnerable": false,
"criteria": "cpe:2.3:o:ui:es-48-lite:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FC3D3131-90F7-4035-88BE-D4090C5D12AB"
},
{
"vulnerable": false,
"criteria": "cpe:2.3:o:ui:es-8-150w:-:*:*:*:*:*:*:*",
"matchCriteriaId": "6A8CD2F2-92BA-4AE9-9D1B-CF4063E417C0"
}
]
}
]
}
],
"references": [
{
"url": "https://community.ui.com/releases/EdgeMAX-EdgeSwitch-Firmware-v1-9-1-v1-9-1/8a87dfc5-70f5-4055-8d67-570db1f5695c%2C",
"source": "support@hackerone.com"
},
{
"url": "https://community.ui.com/releases/Security-advisory-bulletin-014-014/1c32c056-2c64-4e60-ac23-ce7d8f387821%2C",
"source": "support@hackerone.com"
},
{
"url": "https://www.ui.com/download/edgemax",
"source": "support@hackerone.com",
"tags": [
"Product"
]
},
{
"url": "https://community.ui.com/releases/EdgeMAX-EdgeSwitch-Firmware-v1-9-1-v1-9-1/8a87dfc5-70f5-4055-8d67-570db1f5695c%2C",
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://community.ui.com/releases/Security-advisory-bulletin-014-014/1c32c056-2c64-4e60-ac23-ce7d8f387821%2C",
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://www.ui.com/download/edgemax",
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Product"
]
}
]
}