mirror of
https://github.com/fkie-cad/nvd-json-data-feeds.git
synced 2025-05-28 09:11:28 +00:00
86 lines
3.5 KiB
JSON
86 lines
3.5 KiB
JSON
{
|
|
"id": "CVE-2024-10576",
|
|
"sourceIdentifier": "cvd@cert.pl",
|
|
"published": "2024-12-04T12:15:18.463",
|
|
"lastModified": "2024-12-04T12:15:18.463",
|
|
"vulnStatus": "Awaiting Analysis",
|
|
"cveTags": [],
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "Infinix devices contain a pre-loaded \"com.transsion.agingfunction\" application, that\u00a0exposes an unsecured broadcast receiver. An attacker can communicate with the receiver and force the device to perform a factory reset without any Android system permissions.\u00a0\n\nAfter multiple attempts to contact the vendor we did not receive any answer. We suppose this issue affects all Infinix Mobile devices."
|
|
},
|
|
{
|
|
"lang": "es",
|
|
"value": "Los dispositivos Infinix contienen una aplicaci\u00f3n \"com.transsion.agingfunction\" precargada que expone un receptor de transmisi\u00f3n no seguro. Un atacante puede comunicarse con el receptor y forzar al dispositivo a realizar un restablecimiento de f\u00e1brica sin ning\u00fan permiso del sistema Android. Despu\u00e9s de varios intentos de contactar al proveedor, no recibimos ninguna respuesta. Suponemos que este problema afecta a todos los dispositivos m\u00f3viles Infinix."
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV40": [
|
|
{
|
|
"source": "cvd@cert.pl",
|
|
"type": "Secondary",
|
|
"cvssData": {
|
|
"version": "4.0",
|
|
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:N/AU:X/R:I/V:D/RE:X/U:Amber",
|
|
"baseScore": 9.4,
|
|
"baseSeverity": "CRITICAL",
|
|
"attackVector": "LOCAL",
|
|
"attackComplexity": "LOW",
|
|
"attackRequirements": "NONE",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "NONE",
|
|
"vulnConfidentialityImpact": "HIGH",
|
|
"vulnIntegrityImpact": "HIGH",
|
|
"vulnAvailabilityImpact": "HIGH",
|
|
"subConfidentialityImpact": "HIGH",
|
|
"subIntegrityImpact": "HIGH",
|
|
"subAvailabilityImpact": "HIGH",
|
|
"exploitMaturity": "NOT_DEFINED",
|
|
"confidentialityRequirement": "NOT_DEFINED",
|
|
"integrityRequirement": "NOT_DEFINED",
|
|
"availabilityRequirement": "NOT_DEFINED",
|
|
"modifiedAttackVector": "NOT_DEFINED",
|
|
"modifiedAttackComplexity": "NOT_DEFINED",
|
|
"modifiedAttackRequirements": "NOT_DEFINED",
|
|
"modifiedPrivilegesRequired": "NOT_DEFINED",
|
|
"modifiedUserInteraction": "NOT_DEFINED",
|
|
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
|
|
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
|
|
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
|
|
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
|
|
"modifiedSubIntegrityImpact": "NOT_DEFINED",
|
|
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
|
|
"Safety": "NEGLIGIBLE",
|
|
"Automatable": "NOT_DEFINED",
|
|
"Recovery": "IRRECOVERABLE",
|
|
"valueDensity": "DIFFUSE",
|
|
"vulnerabilityResponseEffort": "NOT_DEFINED",
|
|
"providerUrgency": "AMBER"
|
|
}
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "cvd@cert.pl",
|
|
"type": "Secondary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-925"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://cert.pl/en/posts/2024/12/CVE-2024-10576/",
|
|
"source": "cvd@cert.pl"
|
|
},
|
|
{
|
|
"url": "https://cert.pl/posts/2024/12/CVE-2024-10576/",
|
|
"source": "cvd@cert.pl"
|
|
}
|
|
]
|
|
} |