mirror of
https://github.com/fkie-cad/nvd-json-data-feeds.git
synced 2025-05-28 17:21:36 +00:00
135 lines
4.9 KiB
JSON
135 lines
4.9 KiB
JSON
{
|
|
"id": "CVE-2024-12130",
|
|
"sourceIdentifier": "PSIRT@rockwellautomation.com",
|
|
"published": "2024-12-05T18:15:21.507",
|
|
"lastModified": "2024-12-17T15:52:01.670",
|
|
"vulnStatus": "Analyzed",
|
|
"cveTags": [],
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "An \u201cout of bounds read\u201d code execution vulnerability exists in the Rockwell Automation\u00a0Arena\u00ae\n\n that could allow a threat actor to craft a DOE file and force the software to read beyond the boundaries of an allocated memory. If exploited, a threat actor could leverage this vulnerability to execute arbitrary code. To exploit this vulnerability, a legitimate user must execute the malicious code crafted by the threat actor."
|
|
},
|
|
{
|
|
"lang": "es",
|
|
"value": "Existe una vulnerabilidad de ejecuci\u00f3n de c\u00f3digo de \u201cout of bounds read\u201d en Rockwell Automation Arena\u00ae que podr\u00eda permitir que un actor de amenazas manipule un archivo DOE y obligue al software a leer m\u00e1s all\u00e1 de los l\u00edmites de una memoria asignada. Si se explota, un actor de amenazas podr\u00eda aprovechar esta vulnerabilidad para ejecutar c\u00f3digo arbitrario. Para explotar esta vulnerabilidad, un usuario leg\u00edtimo debe ejecutar el c\u00f3digo malicioso manipulado por el actor de amenazas."
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV40": [
|
|
{
|
|
"source": "PSIRT@rockwellautomation.com",
|
|
"type": "Secondary",
|
|
"cvssData": {
|
|
"version": "4.0",
|
|
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
|
|
"baseScore": 8.5,
|
|
"baseSeverity": "HIGH",
|
|
"attackVector": "LOCAL",
|
|
"attackComplexity": "LOW",
|
|
"attackRequirements": "NONE",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "PASSIVE",
|
|
"vulnConfidentialityImpact": "HIGH",
|
|
"vulnIntegrityImpact": "HIGH",
|
|
"vulnAvailabilityImpact": "HIGH",
|
|
"subConfidentialityImpact": "NONE",
|
|
"subIntegrityImpact": "NONE",
|
|
"subAvailabilityImpact": "NONE",
|
|
"exploitMaturity": "NOT_DEFINED",
|
|
"confidentialityRequirement": "NOT_DEFINED",
|
|
"integrityRequirement": "NOT_DEFINED",
|
|
"availabilityRequirement": "NOT_DEFINED",
|
|
"modifiedAttackVector": "NOT_DEFINED",
|
|
"modifiedAttackComplexity": "NOT_DEFINED",
|
|
"modifiedAttackRequirements": "NOT_DEFINED",
|
|
"modifiedPrivilegesRequired": "NOT_DEFINED",
|
|
"modifiedUserInteraction": "NOT_DEFINED",
|
|
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
|
|
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
|
|
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
|
|
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
|
|
"modifiedSubIntegrityImpact": "NOT_DEFINED",
|
|
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
|
|
"Safety": "NOT_DEFINED",
|
|
"Automatable": "NOT_DEFINED",
|
|
"Recovery": "NOT_DEFINED",
|
|
"valueDensity": "NOT_DEFINED",
|
|
"vulnerabilityResponseEffort": "NOT_DEFINED",
|
|
"providerUrgency": "NOT_DEFINED"
|
|
}
|
|
}
|
|
],
|
|
"cvssMetricV31": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
|
|
"baseScore": 7.8,
|
|
"baseSeverity": "HIGH",
|
|
"attackVector": "LOCAL",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "REQUIRED",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "HIGH"
|
|
},
|
|
"exploitabilityScore": 1.8,
|
|
"impactScore": 5.9
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "PSIRT@rockwellautomation.com",
|
|
"type": "Secondary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-125"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-125"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:rockwellautomation:arena:*:*:*:*:*:*:*:*",
|
|
"versionEndIncluding": "16.20.03",
|
|
"matchCriteriaId": "BDAE8F85-64AE-4D05-A68D-F594836762E8"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1713.html",
|
|
"source": "PSIRT@rockwellautomation.com",
|
|
"tags": [
|
|
"Vendor Advisory"
|
|
]
|
|
}
|
|
]
|
|
} |