2025-03-19 15:03:50 +00:00

186 lines
5.1 KiB
JSON

{
"id": "CVE-2024-23788",
"sourceIdentifier": "vultures@jpcert.or.jp",
"published": "2024-02-14T10:15:08.830",
"lastModified": "2025-03-19T14:15:36.007",
"vulnStatus": "Modified",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Server-side request forgery vulnerability in Energy Management Controller with Cloud Services JH-RVB1 /JH-RV11 Ver.B0.1.9.1 and earlier allows a network-adjacent unauthenticated attacker to send an arbitrary HTTP request (GET) from the affected product."
},
{
"lang": "es",
"value": "Vulnerabilidad de server-side request forgery en Energy Management Controller con servicios en la nube JH-RVB1 /JH-RV11 Ver.B0.1.9.1 y anteriores permite que un atacante no autenticado adyacente a la red env\u00ede una solicitud HTTP (GET) arbitraria desde el producto afectado."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "NONE"
},
"exploitabilityScore": 2.8,
"impactScore": 5.2
},
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "NONE"
},
"exploitabilityScore": 3.9,
"impactScore": 5.2
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-918"
}
]
},
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-918"
}
]
}
],
"configurations": [
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:sharp:jh-rvb1_firmware:*:*:*:*:*:*:*:*",
"versionEndIncluding": "b0.1.9.1",
"matchCriteriaId": "B7EC16DF-21FB-473F-8F62-DDBF1C149A9B"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:sharp:jh-rvb1:-:*:*:*:*:*:*:*",
"matchCriteriaId": "27ED2F7C-C3F1-41AA-81DA-3CD5C3B83F88"
}
]
}
]
},
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:sharp:jh-rv11_firmware:*:*:*:*:*:*:*:*",
"versionEndIncluding": "b0.1.9.1",
"matchCriteriaId": "E0A2340C-A0BC-4DD5-A120-F7041D76D776"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:sharp:jh-rv11:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9CF83BDB-56B1-4E80-91C3-AFAA96A0C25C"
}
]
}
]
}
],
"references": [
{
"url": "https://jp.sharp/support/taiyo/info/JVNVU94591337_en.pdf",
"source": "vultures@jpcert.or.jp",
"tags": [
"Third Party Advisory"
]
},
{
"url": "https://jp.sharp/support/taiyo/info/JVNVU94591337_jp.pdf",
"source": "vultures@jpcert.or.jp",
"tags": [
"Third Party Advisory"
]
},
{
"url": "https://jvn.jp/en/vu/JVNVU94591337/",
"source": "vultures@jpcert.or.jp",
"tags": [
"Third Party Advisory"
]
},
{
"url": "https://jp.sharp/support/taiyo/info/JVNVU94591337_en.pdf",
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
]
},
{
"url": "https://jp.sharp/support/taiyo/info/JVNVU94591337_jp.pdf",
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
]
},
{
"url": "https://jvn.jp/en/vu/JVNVU94591337/",
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
]
}
]
}