2024-12-15 03:03:56 +00:00

113 lines
3.3 KiB
JSON

{
"id": "CVE-2024-23812",
"sourceIdentifier": "productcert@siemens.com",
"published": "2024-02-13T09:15:49.953",
"lastModified": "2024-11-21T08:58:28.530",
"vulnStatus": "Modified",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SINEC NMS (All versions < V2.0 SP1). The affected application incorrectly neutralizes special elements when creating a report which could lead to command injection."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en SINEC NMS (Todas las versiones &lt; V2.0 SP1). La aplicaci\u00f3n afectada neutraliza incorrectamente elementos especiales al crear un informe, lo que podr\u00eda dar lugar a la inyecci\u00f3n de comandos."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "productcert@siemens.com",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"baseScore": 8.0,
"baseSeverity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 2.1,
"impactScore": 5.9
},
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9
}
]
},
"weaknesses": [
{
"source": "productcert@siemens.com",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-78"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:sinec_nms:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2.0",
"matchCriteriaId": "A7F0A543-38E1-48B9-A984-259081E49EAA"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:sinec_nms:2.0:-:*:*:*:*:*:*",
"matchCriteriaId": "631E4756-904C-4B57-A991-76BA59D7B901"
}
]
}
]
}
],
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-943925.html",
"source": "productcert@siemens.com",
"tags": [
"Vendor Advisory"
]
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-943925.html",
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
]
}
]
}