mirror of
https://github.com/fkie-cad/nvd-json-data-feeds.git
synced 2025-05-28 09:11:28 +00:00
306 lines
9.0 KiB
JSON
306 lines
9.0 KiB
JSON
{
|
|
"id": "CVE-2024-24851",
|
|
"sourceIdentifier": "talos-cna@cisco.com",
|
|
"published": "2024-05-28T16:15:13.150",
|
|
"lastModified": "2025-02-12T17:30:47.617",
|
|
"vulnStatus": "Analyzed",
|
|
"cveTags": [],
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "A heap-based buffer overflow vulnerability exists in the Programming Software Connection FiBurn functionality of AutomationDirect P3-550E 1.2.10.9. A specially crafted network packet can lead to a buffer overflow. An attacker can send an unauthenticated packet to trigger this vulnerability."
|
|
},
|
|
{
|
|
"lang": "es",
|
|
"value": "Existe una vulnerabilidad de desbordamiento de b\u00fafer de almacenamiento din\u00e1mico en la funcionalidad FiBurn de conexi\u00f3n del software de programaci\u00f3n de AutomationDirect P3-550E 1.2.10.9. Un paquete de red especialmente manipulado puede provocar un desbordamiento del b\u00fafer. Un atacante puede enviar un paquete no autenticado para desencadenar esta vulnerabilidad."
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV31": [
|
|
{
|
|
"source": "talos-cna@cisco.com",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
|
|
"baseScore": 7.5,
|
|
"baseSeverity": "HIGH",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "NONE",
|
|
"integrityImpact": "NONE",
|
|
"availabilityImpact": "HIGH"
|
|
},
|
|
"exploitabilityScore": 3.9,
|
|
"impactScore": 3.6
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "talos-cna@cisco.com",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-805"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-787"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:automationdirect:p3-550e_firmware:1.2.10.9:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "4A393F14-3BD3-44DE-B06F-9235AB62C68F"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:automationdirect:p3-550e_firmware:4.1.1.10:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "5A4772E7-8788-4DB5-98CE-25F0255E0386"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:automationdirect:p3-550e:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "5086EF1F-C3CE-4B5F-A352-67CE332A6C4F"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:automationdirect:p3-550_firmware:1.2.10.9:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "CC227F17-D280-4C74-A73E-8F92158686BE"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:automationdirect:p3-550_firmware:4.1.1.10:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "5CC4A2E2-DF6D-427A-88E6-54FD6D11BDFC"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:automationdirect:p3-550:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "BB4DDF3B-AB0E-4DDD-9865-D4EEDCCA78DE"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:automationdirect:p3-530_firmware:1.2.10.9:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "0462A9CE-4EAA-4C12-9147-F530C42328D3"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:automationdirect:p3-530_firmware:4.1.1.10:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "C8277A48-94C7-40F3-A822-F6311B2CDA94"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:automationdirect:p3-530:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "D58D4140-C719-4EDA-8963-667F9FF21970"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:automationdirect:p2-550_firmware:1.2.10.10:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "AAF96AFD-40E3-4FB6-BAD7-067D9E257A08"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:automationdirect:p2-550_firmware:4.1.1.10:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "D476CC45-B4A1-4210-9347-9854BB0A86AA"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:automationdirect:p2-550:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "386D70E8-70D6-4D25-818C-2218E1B1AC6C"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:automationdirect:p1-550_firmware:1.2.10.10:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "9B7F3A1F-BD96-49A7-A340-0E5E1893326C"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:automationdirect:p1-550_firmware:4.1.1.10:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "27710A58-507C-43BB-849F-7238F5D6D9ED"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:automationdirect:p1-550:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "8FAF2C99-BC5F-4E99-A3A8-FBBDDC24C933"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "AND",
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:automationdirect:p1-540_firmware:1.2.10.10:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "01C6DFFC-374B-4314-9230-53BD01BD6574"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:o:automationdirect:p1-540_firmware:4.1.1.10:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "51095762-A87C-4A1D-A4E2-679462DC8FA9"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": false,
|
|
"criteria": "cpe:2.3:h:automationdirect:p1-540:-:*:*:*:*:*:*:*",
|
|
"matchCriteriaId": "4DB6B9FC-390E-43FD-9DF9-AAB1A9CDAA48"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://community.automationdirect.com/s/internal-database-security-advisory/a4GPE0000003y1F2AQ/sa00025",
|
|
"source": "talos-cna@cisco.com",
|
|
"tags": [
|
|
"Vendor Advisory"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2024-1936",
|
|
"source": "talos-cna@cisco.com",
|
|
"tags": [
|
|
"Exploit",
|
|
"Third Party Advisory"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2024-1936",
|
|
"source": "talos-cna@cisco.com",
|
|
"tags": [
|
|
"Exploit",
|
|
"Third Party Advisory"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://community.automationdirect.com/s/internal-database-security-advisory/a4GPE0000003y1F2AQ/sa00025",
|
|
"source": "af854a3a-2127-422b-91ae-364da2661108",
|
|
"tags": [
|
|
"Vendor Advisory"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2024-1936",
|
|
"source": "af854a3a-2127-422b-91ae-364da2661108",
|
|
"tags": [
|
|
"Exploit",
|
|
"Third Party Advisory"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2024-1936",
|
|
"source": "af854a3a-2127-422b-91ae-364da2661108",
|
|
"tags": [
|
|
"Exploit",
|
|
"Third Party Advisory"
|
|
]
|
|
}
|
|
]
|
|
} |