"lang": "en",
"value": "The Eaton Foreseer software provides users the capability to customize the dashboard in WebView pages. However, the input fields for this feature in the Eaton Foreseer software lacked proper input sanitization on the server-side, which could lead to injection and execution of malicious scripts when abused by bad actors."
},
{
"lang": "es",
"value": "El software Eaton Foreseer ofrece a los usuarios la posibilidad de personalizar el panel de control en las p\u00e1ginas WebView. Sin embargo, los campos de entrada para esta funci\u00f3n en el software Eaton Foreseer carec\u00edan de una desinfecci\u00f3n de entrada adecuada en el lado del servidor, lo que pod\u00eda provocar la inyecci\u00f3n y ejecuci\u00f3n de scripts maliciosos cuando los actores maliciosos los utilizaban de forma abusiva."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "CybersecurityCOE@eaton.com",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"baseScore": 6.7,
"baseSeverity": "MEDIUM",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"privilegesRequired": "HIGH",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 0.8,
"impactScore": 5.9
},
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "REQUIRED",
"scope": "CHANGED",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"availabilityImpact": "NONE"
},
"exploitabilityScore": 2.8,
"impactScore": 2.7
}
]
},
"weaknesses": [
{
"source": "CybersecurityCOE@eaton.com",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-79"
}
]
},
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-79"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:eaton:foreseer_electrical_power_monitoring_system:*:*:*:*:*:*:*:*",
"versionEndExcluding": "7.8.600",
"matchCriteriaId": "9F67BFC9-4D31-42C3-804D-C7F0B6CA8E89"
}
]
}
]
}
],
"references": [
{
"url": "https://www.eaton.com/content/dam/eaton/company/news-insights/cybersecurity/security-bulletins/etn-va-2024-1008.pdf",
"source": "CybersecurityCOE@eaton.com",
"tags": [
"Vendor Advisory"
]
}
]
}