2025-03-02 03:03:52 +00:00

104 lines
9.8 KiB
JSON

{
"id": "CVE-2024-53648",
"sourceIdentifier": "productcert@siemens.com",
"published": "2025-02-11T11:15:14.460",
"lastModified": "2025-02-11T11:15:14.460",
"vulnStatus": "Awaiting Analysis",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V9.90), SIPROTEC 5 6MD85 (CP200) (All versions), SIPROTEC 5 6MD85 (CP300) (All versions < V9.90), SIPROTEC 5 6MD86 (CP200) (All versions), SIPROTEC 5 6MD86 (CP300) (All versions < V9.90), SIPROTEC 5 6MD89 (CP300) (All versions < V9.90), SIPROTEC 5 6MU85 (CP300) (All versions < V9.90), SIPROTEC 5 7KE85 (CP200) (All versions), SIPROTEC 5 7KE85 (CP300) (All versions), SIPROTEC 5 7SA82 (CP100) (All versions), SIPROTEC 5 7SA82 (CP150) (All versions < V9.90), SIPROTEC 5 7SA86 (CP200) (All versions), SIPROTEC 5 7SA86 (CP300) (All versions < V9.90), SIPROTEC 5 7SA87 (CP200) (All versions), SIPROTEC 5 7SA87 (CP300) (All versions < V9.90), SIPROTEC 5 7SD82 (CP100) (All versions), SIPROTEC 5 7SD82 (CP150) (All versions < V9.90), SIPROTEC 5 7SD86 (CP200) (All versions), SIPROTEC 5 7SD86 (CP300) (All versions < V9.90), SIPROTEC 5 7SD87 (CP200) (All versions), SIPROTEC 5 7SD87 (CP300) (All versions < V9.90), SIPROTEC 5 7SJ81 (CP100) (All versions), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.90), SIPROTEC 5 7SJ82 (CP100) (All versions), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.90), SIPROTEC 5 7SJ85 (CP200) (All versions), SIPROTEC 5 7SJ85 (CP300) (All versions < V9.90), SIPROTEC 5 7SJ86 (CP200) (All versions), SIPROTEC 5 7SJ86 (CP300) (All versions < V9.90), SIPROTEC 5 7SK82 (CP100) (All versions), SIPROTEC 5 7SK82 (CP150) (All versions < V9.90), SIPROTEC 5 7SK85 (CP200) (All versions), SIPROTEC 5 7SK85 (CP300) (All versions < V9.90), SIPROTEC 5 7SL82 (CP100) (All versions), SIPROTEC 5 7SL82 (CP150) (All versions < V9.90), SIPROTEC 5 7SL86 (CP200) (All versions), SIPROTEC 5 7SL86 (CP300) (All versions < V9.90), SIPROTEC 5 7SL87 (CP200) (All versions), SIPROTEC 5 7SL87 (CP300) (All versions < V9.90), SIPROTEC 5 7SS85 (CP200) (All versions), SIPROTEC 5 7SS85 (CP300) (All versions < V9.90), SIPROTEC 5 7ST85 (CP200) (All versions), SIPROTEC 5 7ST85 (CP300) (All versions), SIPROTEC 5 7ST86 (CP300) (All versions), SIPROTEC 5 7SX82 (CP150) (All versions < V9.90), SIPROTEC 5 7SX85 (CP300) (All versions < V9.90), SIPROTEC 5 7SY82 (CP150) (All versions < V9.90), SIPROTEC 5 7UM85 (CP300) (All versions < V9.90), SIPROTEC 5 7UT82 (CP100) (All versions), SIPROTEC 5 7UT82 (CP150) (All versions < V9.90), SIPROTEC 5 7UT85 (CP200) (All versions), SIPROTEC 5 7UT85 (CP300) (All versions < V9.90), SIPROTEC 5 7UT86 (CP200) (All versions), SIPROTEC 5 7UT86 (CP300) (All versions < V9.90), SIPROTEC 5 7UT87 (CP200) (All versions), SIPROTEC 5 7UT87 (CP300) (All versions < V9.90), SIPROTEC 5 7VE85 (CP300) (All versions < V9.90), SIPROTEC 5 7VK87 (CP200) (All versions), SIPROTEC 5 7VK87 (CP300) (All versions < V9.90), SIPROTEC 5 7VU85 (CP300) (All versions < V9.90), SIPROTEC 5 Compact 7SX800 (CP050) (All versions < V9.90). Affected devices do not properly limit access to a development shell accessible over a physical interface. This could allow an unauthenticated attacker with physical access to the device to execute arbitrary commands on the device."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en SIPROTEC 5 6MD84 (CP300) (Todas las versiones &lt; V9.90), SIPROTEC 5 6MD85 (CP200) (Todas las versiones), SIPROTEC 5 6MD85 (CP300) (Todas las versiones &lt; V9.90), SIPROTEC 5 6MD86 (CP200) (Todas las versiones), SIPROTEC 5 6MD86 (CP300) (Todas las versiones &lt; V9.90), SIPROTEC 5 6MD89 (CP300) (Todas las versiones &lt; V9.90), SIPROTEC 5 6MU85 (CP300) (Todas las versiones &lt; V9.90), SIPROTEC 5 7KE85 (CP200) (Todas las versiones), SIPROTEC 5 7KE85 (CP300) (Todas las versiones), SIPROTEC 5 7SA82 (CP100) (Todas las versiones), SIPROTEC 5 7SA82 (CP150) (Todas las versiones &lt; V9.90), SIPROTEC 5 7SA86 (CP200) (Todas las versiones), SIPROTEC 5 7SA86 (CP300) (Todas las versiones &lt; V9.90), SIPROTEC 5 7SA87 (CP200) (Todas las versiones), SIPROTEC 5 7SA87 (CP300) (Todas las versiones &lt; V9.90), SIPROTEC 5 7SD82 (CP100) (Todas las versiones), SIPROTEC 5 7SD82 (CP150) (Todas las versiones &lt; V9.90), SIPROTEC 5 7SD86 (CP200) (Todas las versiones), SIPROTEC 5 7SD86 (CP300) (Todas las versiones &lt; V9.90), SIPROTEC 5 7SD87 (CP200) (Todas las versiones), SIPROTEC 5 7SD87 (CP300) (Todas las versiones &lt; V9.90), SIPROTEC 5 7SJ81 (CP100) (Todas las versiones), SIPROTEC 5 7SJ81 (CP150) (Todas las versiones &lt; V9.90), SIPROTEC 5 7SJ82 (CP100) (Todas las versiones), SIPROTEC 5 7SJ82 (CP150) (Todas las versiones &lt; V9.90), SIPROTEC 5 7SJ85 (CP200) (Todas las versiones), SIPROTEC 5 7SJ85 (CP300) (Todas las versiones &lt; V9.90), SIPROTEC 5 7SJ86 (CP200) (Todas las versiones), SIPROTEC 5 7SJ86 (CP300) (Todas las versiones &lt; V9.90), SIPROTEC 5 7SK82 (CP100) (Todas las versiones), SIPROTEC 5 7SK82 (CP150) (Todas las versiones &lt; V9.90), SIPROTEC 5 7SK85 (CP200) (Todas las versiones), SIPROTEC 5 7SK85 (CP300) (Todas las versiones &lt; V9.90), SIPROTEC 5 7SL82 (CP100) (Todas las versiones), SIPROTEC 5 7SL82 (CP150) (Todas las versiones &lt; V9.90), SIPROTEC 5 7SL86 (CP200) (Todas las versiones), SIPROTEC 5 7SL86 (CP300) (Todas las versiones &lt; V9.90), SIPROTEC 5 7SL87 (CP200) (Todas las versiones), SIPROTEC 5 7SL87 (CP300) (Todas las versiones &lt; V9.90), SIPROTEC 5 7SS85 (CP200) (Todas las versiones), SIPROTEC 5 7SS85 (CP300) (Todas las versiones &lt; V9.90), SIPROTEC 5 7ST85 (CP200) (Todas las versiones), SIPROTEC 5 7ST85 (CP300) (Todas las versiones), SIPROTEC 5 7ST86 (CP300) (Todas las versiones), SIPROTEC 5 7SX82 (CP150) (Todas las versiones &lt; V9.90), SIPROTEC 5 7SX85 (CP300) (Todas las versiones &lt; V9.90), SIPROTEC 5 7SY82 (CP150) (Todas las versiones &lt; V9.90), SIPROTEC 5 7UM85 (CP300) (Todas las versiones &lt; V9.90), SIPROTEC 5 7UT82 (CP100) (Todas las versiones), SIPROTEC 5 7UT82 (CP150) (Todas las versiones &lt; V9.90), SIPROTEC 5 7UT85 (CP200) (Todas las versiones), SIPROTEC 5 7UT85 (CP300) (Todas las versiones &lt; V9.90), SIPROTEC 5 7UT86 (CP200) (Todas las versiones), SIPROTEC 5 7UT86 (CP300) (Todas las versiones &lt; V9.90), SIPROTEC 5 7UT87 (CP200) (Todas las versiones), SIPROTEC 5 7UT87 (CP300) (Todas las versiones &lt; V9.90), SIPROTEC 5 7VE85 (CP300) (Todas las versiones &lt; V9.90), SIPROTEC 5 7VK87 (CP200) (Todas las versiones), SIPROTEC 5 7VK87 (CP300) (Todas las versiones &lt; V9.90), SIPROTEC 5 7VU85 (CP300) (Todas las versiones &lt; V9.90), SIPROTEC 5 Compact 7SX800 (CP050) (Todas las versiones &lt; V9.90). Los dispositivos afectados no limitan correctamente el acceso a un shell de desarrollo accesible a trav\u00e9s de una interfaz f\u00edsica. Esto podr\u00eda permitir que un atacante no autenticado con acceso f\u00edsico al dispositivo ejecute comandos arbitrarios en el dispositivo."
}
],
"metrics": {
"cvssMetricV40": [
{
"source": "productcert@siemens.com",
"type": "Secondary",
"cvssData": {
"version": "4.0",
"vectorString": "CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"baseScore": 7.0,
"baseSeverity": "HIGH",
"attackVector": "PHYSICAL",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"subAvailabilityImpact": "NONE",
"exploitMaturity": "NOT_DEFINED",
"confidentialityRequirement": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"availabilityRequirement": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"valueDensity": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED"
}
}
],
"cvssMetricV31": [
{
"source": "productcert@siemens.com",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"attackVector": "PHYSICAL",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 0.9,
"impactScore": 5.9
}
]
},
"weaknesses": [
{
"source": "productcert@siemens.com",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-489"
}
]
}
],
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-687955.html",
"source": "productcert@siemens.com"
}
]
}