2021-01-26 18:02:03 +00:00
|
|
|
{
|
|
|
|
"CVE_data_meta": {
|
2021-03-09 12:55:18 +00:00
|
|
|
"ASSIGNER": "productcert@siemens.com",
|
2021-01-26 18:02:03 +00:00
|
|
|
"ID": "CVE-2021-25667",
|
2021-03-09 12:55:18 +00:00
|
|
|
"STATE": "PUBLIC"
|
|
|
|
},
|
|
|
|
"data_format": "MITRE",
|
|
|
|
"data_version": "4.0",
|
|
|
|
"data_type": "CVE",
|
|
|
|
"affects": {
|
|
|
|
"vendor": {
|
|
|
|
"vendor_data": [
|
|
|
|
{
|
|
|
|
"vendor_name": "Siemens",
|
|
|
|
"product": {
|
|
|
|
"product_data": [
|
|
|
|
{
|
|
|
|
"product_name": "RUGGEDCOM RM1224",
|
|
|
|
"version": {
|
|
|
|
"version_data": [
|
|
|
|
{
|
2021-04-13 11:40:52 +01:00
|
|
|
"version_value": "All versions >= V4.3 and < V6.4"
|
2021-03-09 12:55:18 +00:00
|
|
|
}
|
|
|
|
]
|
|
|
|
}
|
|
|
|
},
|
|
|
|
{
|
|
|
|
"product_name": "SCALANCE M-800",
|
|
|
|
"version": {
|
|
|
|
"version_data": [
|
|
|
|
{
|
2021-04-13 11:40:52 +01:00
|
|
|
"version_value": "All versions >= V4.3 and < V6.4"
|
2021-03-09 12:55:18 +00:00
|
|
|
}
|
|
|
|
]
|
|
|
|
}
|
|
|
|
},
|
|
|
|
{
|
|
|
|
"product_name": "SCALANCE S615",
|
|
|
|
"version": {
|
|
|
|
"version_data": [
|
|
|
|
{
|
2021-04-13 11:40:52 +01:00
|
|
|
"version_value": "All versions >= V4.3 and < V6.4"
|
2021-03-09 12:55:18 +00:00
|
|
|
}
|
|
|
|
]
|
|
|
|
}
|
|
|
|
},
|
|
|
|
{
|
|
|
|
"product_name": "SCALANCE SC-600 Family",
|
|
|
|
"version": {
|
|
|
|
"version_data": [
|
|
|
|
{
|
|
|
|
"version_value": "All versions >= V2.0 and < V2.1.3"
|
|
|
|
}
|
|
|
|
]
|
|
|
|
}
|
|
|
|
},
|
|
|
|
{
|
2021-04-13 11:40:52 +01:00
|
|
|
"product_name": "SCALANCE XB-200",
|
|
|
|
"version": {
|
|
|
|
"version_data": [
|
|
|
|
{
|
|
|
|
"version_value": "All versions < V4.1"
|
|
|
|
}
|
|
|
|
]
|
|
|
|
}
|
|
|
|
},
|
|
|
|
{
|
|
|
|
"product_name": "SCALANCE XC-200",
|
|
|
|
"version": {
|
|
|
|
"version_data": [
|
|
|
|
{
|
|
|
|
"version_value": "All versions < V4.1"
|
|
|
|
}
|
|
|
|
]
|
|
|
|
}
|
|
|
|
},
|
|
|
|
{
|
|
|
|
"product_name": "SCALANCE XF-200BA",
|
2021-03-09 12:55:18 +00:00
|
|
|
"version": {
|
|
|
|
"version_data": [
|
|
|
|
{
|
|
|
|
"version_value": "All versions < V4.1"
|
|
|
|
}
|
|
|
|
]
|
|
|
|
}
|
|
|
|
},
|
|
|
|
{
|
|
|
|
"product_name": "SCALANCE XM400",
|
|
|
|
"version": {
|
|
|
|
"version_data": [
|
|
|
|
{
|
|
|
|
"version_value": "All versions < V6.2"
|
|
|
|
}
|
|
|
|
]
|
|
|
|
}
|
|
|
|
},
|
|
|
|
{
|
2021-04-13 11:40:52 +01:00
|
|
|
"product_name": "SCALANCE XP-200",
|
2021-03-09 12:55:18 +00:00
|
|
|
"version": {
|
|
|
|
"version_data": [
|
|
|
|
{
|
2021-04-13 11:40:52 +01:00
|
|
|
"version_value": "All versions < V4.1"
|
2021-03-09 12:55:18 +00:00
|
|
|
}
|
|
|
|
]
|
|
|
|
}
|
|
|
|
},
|
|
|
|
{
|
2021-04-13 11:40:52 +01:00
|
|
|
"product_name": "SCALANCE XR-300WG",
|
2021-03-09 12:55:18 +00:00
|
|
|
"version": {
|
|
|
|
"version_data": [
|
|
|
|
{
|
|
|
|
"version_value": "All versions < V4.1"
|
|
|
|
}
|
|
|
|
]
|
|
|
|
}
|
2021-04-13 11:40:52 +01:00
|
|
|
},
|
|
|
|
{
|
|
|
|
"product_name": "SCALANCE XR500",
|
|
|
|
"version": {
|
|
|
|
"version_data": [
|
|
|
|
{
|
|
|
|
"version_value": "All versions < V6.2"
|
|
|
|
}
|
|
|
|
]
|
|
|
|
}
|
2021-03-09 12:55:18 +00:00
|
|
|
}
|
|
|
|
]
|
|
|
|
}
|
|
|
|
}
|
|
|
|
]
|
|
|
|
}
|
|
|
|
},
|
|
|
|
"problemtype": {
|
|
|
|
"problemtype_data": [
|
|
|
|
{
|
|
|
|
"description": [
|
|
|
|
{
|
|
|
|
"lang": "eng",
|
|
|
|
"value": "CWE-121: Stack-based Buffer Overflow"
|
|
|
|
}
|
|
|
|
]
|
|
|
|
}
|
|
|
|
]
|
2021-01-26 18:02:03 +00:00
|
|
|
},
|
|
|
|
"description": {
|
|
|
|
"description_data": [
|
|
|
|
{
|
|
|
|
"lang": "eng",
|
2021-04-22 21:01:04 +00:00
|
|
|
"value": "A vulnerability has been identified in RUGGEDCOM RM1224 (All versions >= V4.3 and < V6.4), SCALANCE M-800 (All versions >= V4.3 and < V6.4), SCALANCE S615 (All versions >= V4.3 and < V6.4), SCALANCE SC-600 Family (All versions >= V2.0 and < V2.1.3), SCALANCE XB-200 (All versions < V4.1), SCALANCE XC-200 (All versions < V4.1), SCALANCE XF-200BA (All versions < V4.1), SCALANCE XM400 (All versions < V6.2), SCALANCE XP-200 (All versions < V4.1), SCALANCE XR-300WG (All versions < V4.1), SCALANCE XR500 (All versions < V6.2). Affected devices contain a stack-based buffer overflow vulnerability in the handling of STP BPDU frames that could allow a remote attacker to trigger a denial-of-service condition or potentially remote code execution. Successful exploitation requires the passive listening feature of the device to be active."
|
2021-03-09 12:55:18 +00:00
|
|
|
}
|
|
|
|
]
|
|
|
|
},
|
|
|
|
"references": {
|
|
|
|
"reference_data": [
|
|
|
|
{
|
2021-03-15 18:00:44 +00:00
|
|
|
"refsource": "MISC",
|
|
|
|
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979775.pdf",
|
|
|
|
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-979775.pdf"
|
2021-04-15 22:00:42 +00:00
|
|
|
},
|
|
|
|
{
|
|
|
|
"refsource": "MISC",
|
|
|
|
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-068-03",
|
|
|
|
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-068-03"
|
2021-01-26 18:02:03 +00:00
|
|
|
}
|
|
|
|
]
|
|
|
|
}
|
|
|
|
}
|