2023-04-24 12:24:31 +02:00
{
"id" : "CVE-2022-22727" ,
"sourceIdentifier" : "cybersecurity@se.com" ,
"published" : "2022-02-04T23:15:13.303" ,
2024-11-23 15:12:23 +00:00
"lastModified" : "2024-11-21T06:47:20.010" ,
2023-11-07 21:03:21 +00:00
"vulnStatus" : "Modified" ,
2024-12-08 03:06:42 +00:00
"cveTags" : [ ] ,
2023-04-24 12:24:31 +02:00
"descriptions" : [
{
"lang" : "en" ,
2023-11-07 21:03:21 +00:00
"value" : "A CWE-20: Improper Input Validation vulnerability exists that could allow an unauthenticated attacker to view data, change settings, impact availability of the software, or potentially impact a user\ufffds local machine when the user clicks a specially crafted link. Affected Product: EcoStruxure Power Monitoring Expert (Versions 2020 and prior)"
2023-04-24 12:24:31 +02:00
} ,
{
"lang" : "es" ,
"value" : "Una CWE-20: Se presenta una vulnerabilidad de Comprobaci\u00f3n de Entrada Inapropiada que podr\u00eda permitir a un atacante no autenticado visualizar datos, cambiar la configuraci\u00f3n, afectar a la disponibilidad del software o potencialmente afectar a la m\u00e1quina local de un usuario cuando \u00e9ste hace clic en un enlace especialmente dise\u00f1ado. Producto afectado: EcoStruxure Power Monitoring Expert (versiones 2020 y anteriores)"
}
] ,
"metrics" : {
"cvssMetricV31" : [
{
"source" : "nvd@nist.gov" ,
"type" : "Primary" ,
"cvssData" : {
"version" : "3.1" ,
"vectorString" : "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" ,
2024-11-23 15:12:23 +00:00
"baseScore" : 8.8 ,
"baseSeverity" : "HIGH" ,
2023-04-24 12:24:31 +02:00
"attackVector" : "NETWORK" ,
"attackComplexity" : "LOW" ,
"privilegesRequired" : "NONE" ,
"userInteraction" : "REQUIRED" ,
"scope" : "UNCHANGED" ,
"confidentialityImpact" : "HIGH" ,
"integrityImpact" : "HIGH" ,
2024-11-23 15:12:23 +00:00
"availabilityImpact" : "HIGH"
2023-04-24 12:24:31 +02:00
} ,
"exploitabilityScore" : 2.8 ,
"impactScore" : 5.9
}
] ,
"cvssMetricV2" : [
{
"source" : "nvd@nist.gov" ,
"type" : "Primary" ,
"cvssData" : {
"version" : "2.0" ,
"vectorString" : "AV:N/AC:M/Au:N/C:C/I:C/A:C" ,
2024-11-23 15:12:23 +00:00
"baseScore" : 9.3 ,
2023-04-24 12:24:31 +02:00
"accessVector" : "NETWORK" ,
"accessComplexity" : "MEDIUM" ,
"authentication" : "NONE" ,
"confidentialityImpact" : "COMPLETE" ,
"integrityImpact" : "COMPLETE" ,
2024-11-23 15:12:23 +00:00
"availabilityImpact" : "COMPLETE"
2023-04-24 12:24:31 +02:00
} ,
"baseSeverity" : "HIGH" ,
"exploitabilityScore" : 8.6 ,
"impactScore" : 10.0 ,
"acInsufInfo" : false ,
"obtainAllPrivilege" : false ,
"obtainUserPrivilege" : false ,
"obtainOtherPrivilege" : false ,
"userInteractionRequired" : true
}
]
} ,
"weaknesses" : [
{
2024-04-04 08:46:00 +00:00
"source" : "cybersecurity@se.com" ,
2024-12-15 03:03:56 +00:00
"type" : "Primary" ,
2023-04-24 12:24:31 +02:00
"description" : [
{
"lang" : "en" ,
"value" : "CWE-20"
}
]
} ,
{
"source" : "nvd@nist.gov" ,
"type" : "Secondary" ,
"description" : [
{
"lang" : "en" ,
"value" : "CWE-20"
}
]
}
] ,
"configurations" : [
{
"nodes" : [
{
"operator" : "OR" ,
"negate" : false ,
"cpeMatch" : [
{
"vulnerable" : true ,
"criteria" : "cpe:2.3:a:schneider-electric:ecostruxure_power_monitoring_expert:*:*:*:*:*:*:*:*" ,
"versionEndIncluding" : "2020" ,
"matchCriteriaId" : "F3E7251E-B20A-40A4-9CAD-CD757E2B1450"
}
]
}
]
}
] ,
"references" : [
{
"url" : "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-07" ,
"source" : "cybersecurity@se.com" ,
"tags" : [
"Patch" ,
"Vendor Advisory"
]
2024-11-23 15:12:23 +00:00
} ,
{
"url" : "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-07" ,
"source" : "af854a3a-2127-422b-91ae-364da2661108" ,
"tags" : [
"Patch" ,
"Vendor Advisory"
]
2023-04-24 12:24:31 +02:00
}
]
}