"id": "CVE-2022-22727",
"sourceIdentifier": "cybersecurity@se.com",
"published": "2022-02-04T23:15:13.303",
"lastModified": "2024-11-21T06:47:20.010",
"vulnStatus": "Modified",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A CWE-20: Improper Input Validation vulnerability exists that could allow an unauthenticated attacker to view data, change settings, impact availability of the software, or potentially impact a user\ufffds local machine when the user clicks a specially crafted link. Affected Product: EcoStruxure Power Monitoring Expert (Versions 2020 and prior)"
},
{
"lang": "es",
"value": "Una CWE-20: Se presenta una vulnerabilidad de Comprobaci\u00f3n de Entrada Inapropiada que podr\u00eda permitir a un atacante no autenticado visualizar datos, cambiar la configuraci\u00f3n, afectar a la disponibilidad del software o potencialmente afectar a la m\u00e1quina local de un usuario cuando \u00e9ste hace clic en un enlace especialmente dise\u00f1ado. Producto afectado: EcoStruxure Power Monitoring Expert (versiones 2020 y anteriores)"
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "REQUIRED",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
"baseScore": 9.3,
"accessVector": "NETWORK",
"accessComplexity": "MEDIUM",
"authentication": "NONE",
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"availabilityImpact": "COMPLETE"
},
"baseSeverity": "HIGH",
"exploitabilityScore": 8.6,
"impactScore": 10.0,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": true
}
]
},
"weaknesses": [
{
"source": "cybersecurity@se.com",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-20"
}
]
},
{
"source": "nvd@nist.gov",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-20"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:schneider-electric:ecostruxure_power_monitoring_expert:*:*:*:*:*:*:*:*",
"versionEndIncluding": "2020",
"matchCriteriaId": "F3E7251E-B20A-40A4-9CAD-CD757E2B1450"
}
]
}
]
}
],
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-07",
"source": "cybersecurity@se.com",
"tags": [
"Patch",
"Vendor Advisory"
]
},
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-07",
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
]
}
]
}