146 lines
4.1 KiB
JSON
Raw Normal View History

2023-04-24 12:24:31 +02:00
{
"id": "CVE-2021-33841",
"sourceIdentifier": "cve-coordination@incibe.es",
"published": "2021-06-09T12:15:07.893",
"lastModified": "2021-06-21T19:27:50.607",
"vulnStatus": "Analyzed",
"descriptions": [
{
"lang": "en",
"value": "SGE-PLC1000 device, in its 0.9.2b firmware version, does not handle some requests correctly, allowing a remote attacker to inject code into the operating system with maximum privileges."
},
{
"lang": "es",
"value": "Un dispositivo SGE-PLC1000, en su versi\u00f3n de firmware 0.9.2b, no maneja algunas petici\u00f3nes correctamente, permitiendo a un atacante remoto inyectar c\u00f3digo en el sistema operativo con m\u00e1ximos privilegios"
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9
},
{
"source": "cve-coordination@incibe.es",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"attackVector": "ADJACENT_NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "CHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 9.6,
"baseSeverity": "CRITICAL"
},
"exploitabilityScore": 2.8,
"impactScore": 6.0
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"accessVector": "NETWORK",
"accessComplexity": "LOW",
"authentication": "NONE",
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0
},
"baseSeverity": "HIGH",
"exploitabilityScore": 10.0,
"impactScore": 10.0,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-78"
}
]
},
{
"source": "cve-coordination@incibe.es",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-78"
}
]
}
],
"configurations": [
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:circutor:sge-plc1000_firmware:0.9.2b:*:*:*:*:*:*:*",
"matchCriteriaId": "5D6B02E0-DE36-45F5-AD3D-908E30548661"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:circutor:sge-plc1000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FFF41215-1018-42DD-9A7E-BBC2E5B4522D"
}
]
}
]
}
],
"references": [
{
"url": "https://www.incibe-cert.es/en/early-warning/ics-advisories/circutor-sge-plc1000-os-command-injection",
"source": "cve-coordination@incibe.es",
"tags": [
"Third Party Advisory"
]
}
]
}