2024-07-14 02:06:08 +00:00

131 lines
3.9 KiB
JSON

{
"id": "CVE-2023-36635",
"sourceIdentifier": "psirt@fortinet.com",
"published": "2023-09-07T13:15:08.433",
"lastModified": "2023-11-07T04:16:39.410",
"vulnStatus": "Modified",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An improper access control in Fortinet FortiSwitchManager version 7.2.0 through 7.2.2\r\n7.0.0 through 7.0.1 may allow a remote authenticated read-only user to modify the interface settings via the API."
},
{
"lang": "es",
"value": "Un control de acceso incorrecto en Fortinet FortiSwitchManager, versiones 7.2.0 a 7.2.2 y versiones 7.0.0 a 7.0.1, puede permitir que un usuario remoto autenticado con permisos de solo lectura modifique la configuraci\u00f3n de la interfaz a trav\u00e9s de la API."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"baseSeverity": "MEDIUM"
},
"exploitabilityScore": 2.8,
"impactScore": 1.4
},
{
"source": "psirt@fortinet.com",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:H",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"availabilityImpact": "HIGH",
"baseScore": 7.1,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 2.8,
"impactScore": 4.2
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "NVD-CWE-Other"
}
]
},
{
"source": "psirt@fortinet.com",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-284"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:fortinet:fortiswitchmanager:7.0.0:*:*:*:*:*:*:*",
"matchCriteriaId": "5B4A6B0D-1614-443B-8EBA-A8FBC2E1A832"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:fortinet:fortiswitchmanager:7.0.1:*:*:*:*:*:*:*",
"matchCriteriaId": "331A1766-4EBA-4519-A8ED-E0DD68A187E9"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:fortinet:fortiswitchmanager:7.2.0:*:*:*:*:*:*:*",
"matchCriteriaId": "2B73D78B-2270-45B7-854E-F985B8D88F3B"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:fortinet:fortiswitchmanager:7.2.1:*:*:*:*:*:*:*",
"matchCriteriaId": "469E9E1C-154C-41CB-AC83-FBE5E6FA83EB"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:fortinet:fortiswitchmanager:7.2.2:*:*:*:*:*:*:*",
"matchCriteriaId": "959248C7-DC92-4968-87F9-2A2CDF84F7BE"
}
]
}
]
}
],
"references": [
{
"url": "https://fortiguard.com/psirt/FG-IR-22-174",
"source": "psirt@fortinet.com",
"tags": [
"Not Applicable",
"Vendor Advisory"
]
}
]
}