2024-07-14 02:06:08 +00:00

116 lines
3.7 KiB
JSON

{
"id": "CVE-2023-46717",
"sourceIdentifier": "psirt@fortinet.com",
"published": "2024-03-12T15:15:46.487",
"lastModified": "2024-03-21T21:04:18.200",
"vulnStatus": "Analyzed",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An improper authentication vulnerability [CWE-287] in FortiOS versions 7.4.1 and below, versions 7.2.6 and below, and versions 7.0.12 and below when configured with FortiAuthenticator in HA may allow a readonly user to gain read-write access via successive login attempts."
},
{
"lang": "es",
"value": "Una vulnerabilidad de autenticaci\u00f3n incorrecta [CWE-287] en las versiones 7.4.1 y anteriores de FortiOS, las versiones 7.2.6 y siguientes y las versiones 7.0.12 y siguientes cuando se configura con FortiAuthenticator en HA puede permitir que un usuario de solo lectura obtenga acceso de lectura y escritura a trav\u00e9s de intentos sucesivos de inicio de sesi\u00f3n."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9
},
{
"source": "psirt@fortinet.com",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H",
"attackVector": "NETWORK",
"attackComplexity": "HIGH",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 1.6,
"impactScore": 5.9
}
]
},
"weaknesses": [
{
"source": "psirt@fortinet.com",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-287"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:fortinet:fortios:*:*:*:*:*:*:*:*",
"versionStartIncluding": "7.0.0",
"versionEndExcluding": "7.0.13",
"matchCriteriaId": "D25F9C04-C7FD-4B1F-A194-CA69E5DE903C"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:o:fortinet:fortios:*:*:*:*:*:*:*:*",
"versionStartIncluding": "7.2.0",
"versionEndExcluding": "7.2.7",
"matchCriteriaId": "553C4BA9-953B-4017-8498-785BDA7A3006"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:o:fortinet:fortios:*:*:*:*:*:*:*:*",
"versionStartIncluding": "7.4.0",
"versionEndExcluding": "7.4.2",
"matchCriteriaId": "4316C2EA-3D6E-4A0C-B81D-ADCE040E03E0"
}
]
}
]
}
],
"references": [
{
"url": "https://fortiguard.com/psirt/FG-IR-23-424",
"source": "psirt@fortinet.com",
"tags": [
"Vendor Advisory"
]
}
]
}