"id": "CVE-2023-41032",
"sourceIdentifier": "productcert@siemens.com",
"published": "2023-09-12T10:15:29.690",
"lastModified": "2024-02-16T14:25:44.303",
"vulnStatus": "Analyzed",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Parasolid V34.1 (All versions < V34.1.258), Parasolid V35.0 (All versions < V35.0.253), Parasolid V35.1 (All versions < V35.1.184), Parasolid V36.0 (All versions < V36.0.142), Simcenter Femap V2301 (All versions < V2301.0003), Simcenter Femap V2306 (All versions < V2306.0001). The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21263)"
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en Parasolid V34.1 (todas las versiones &lt; V34.1.258), Parasolid V35.0 (todas las versiones &lt; V35.0.253), Parasolid V35.1 (todas las versiones &lt; V35.1.184), Parasolid V36.0 (todas las versiones &lt; V36.0.142). La aplicaci\u00f3n afectada contiene una escritura fuera de los l\u00edmites m\u00e1s all\u00e1 del final de una estructura asignada mientras analiza archivos X_T especialmente manipulados. Esto podr\u00eda permitir a un atacante ejecutar c\u00f3digo en el contexto del proceso actual. (ZDI-CAN-21263)"
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "productcert@siemens.com",
"type": "Primary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "REQUIRED",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-787"
}
]
},
{
"source": "productcert@siemens.com",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-787"
}
]
}
],
"configurations": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*",
"versionStartIncluding": "34.1",
"versionEndExcluding": "34.1.258",
"matchCriteriaId": "E7751190-C386-451B-88B5-4BB4DCBFCE44"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*",
"versionStartIncluding": "35.0",
"versionEndExcluding": "35.0.253",
"matchCriteriaId": "0CC7B08D-C9CF-4B68-90A8-8D2DF3CB5154"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*",
"versionStartIncluding": "35.1",
"versionEndExcluding": "35.1.184",
"matchCriteriaId": "3881FB7A-8951-48F6-A948-7C670C11B2B3"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*",
"versionStartIncluding": "36.0",
"versionEndExcluding": "36.0.142",
"matchCriteriaId": "B2873D5B-2501-4B02-8B68-347B69FC8D43"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:simcenter_femap:*:*:*:*:*:*:*:*",
"versionStartIncluding": "2301.0",
"versionEndExcluding": "2301.0003",
"matchCriteriaId": "FC710071-C7AC-4ED0-9550-5FBE8FCD37AE"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:simcenter_femap:*:*:*:*:*:*:*:*",
"versionStartIncluding": "2306.0",
"versionEndExcluding": "2306.0001",
"matchCriteriaId": "8E84C2D3-EF31-46E9-884A-7EB00B515D23"
}
]
}
]
}
],
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-190839.pdf",
"source": "productcert@siemens.com",
"tags": [
"Vendor Advisory"
]
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-887122.pdf",
"source": "productcert@siemens.com",
"tags": [
"Vendor Advisory"
]
},
{
"url": "https://www.bentley.com/advisories/be-2023-0004/",
"source": "productcert@siemens.com",
"tags": [
"Third Party Advisory"
]
}
]
}