"id": "CVE-2024-23798",
|
|
"sourceIdentifier": "productcert@siemens.com",
|
|
"published": "2024-02-13T09:15:48.170",
|
|
"lastModified": "2024-02-13T19:21:49.827",
|
|
"vulnStatus": "Analyzed",
|
|
"cveTags": [],
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0012), Tecnomatix Plant Simulation V2302 (All versions < V2302.0006). The affected applications contain a stack overflow vulnerability while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process."
|
|
},
|
|
{
|
|
"lang": "es",
|
|
"value": "Se ha identificado una vulnerabilidad en Tecnomatix Plant Simulation V2201 (Todas las versiones < V2201.0012), Tecnomatix Plant Simulation V2302 (Todas las versiones < V2302.0006). Las aplicaciones afectadas contienen una vulnerabilidad de desbordamiento de pila al analizar archivos WRL especialmente manipulados. Esto podr\u00eda permitir a un atacante ejecutar c\u00f3digo en el contexto del proceso actual."
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV31": [
|
|
{
|
|
"source": "productcert@siemens.com",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
|
|
"attackVector": "LOCAL",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "REQUIRED",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "HIGH",
|
|
"baseScore": 7.8,
|
|
"baseSeverity": "HIGH"
|
|
},
|
|
"exploitabilityScore": 1.8,
|
|
"impactScore": 5.9
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-787"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"source": "productcert@siemens.com",
|
|
"type": "Secondary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-121"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:*",
|
|
"versionEndExcluding": "2201.0012",
|
|
"matchCriteriaId": "92315B86-671A-48F9-9D7D-C638DABD8520"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:*",
|
|
"versionStartIncluding": "2302.0",
|
|
"versionEndExcluding": "2302.0006",
|
|
"matchCriteriaId": "D222D65A-C271-4BE4-8139-DB5F38D053D5"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://cert-portal.siemens.com/productcert/html/ssa-017796.html",
|
|
"source": "productcert@siemens.com",
|
|
"tags": [
|
|
"Mitigation",
|
|
"Patch",
|
|
"Vendor Advisory"
|
|
]
|
|
}
|
|
]
|
|
} |