"lang": "en",
"value": "A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions < V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions < V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions < V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions < V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions < 1.02.02; SIPROTEC 7SJ686 : All versions < V 4.87; SIPROTEC 7UT686 : All versions < V 4.02; SIPROTEC 7SD686 : All versions < V 4.05; SIPROTEC 7SJ66 : All versions < V 4.30. Attackers with network access to the device's web interface (port 80/tcp) could possibly circumvent authentication and perform certain administrative operations. A legitimate user must be logged into the web interface for the attack to be successful."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en la variante de Firmware PROFINET IO para los m\u00f3dulos EN100 Ethernet: en todas las versiones anteriores a V1.04.01; la variante de Firmware Modbus TCP para los m\u00f3dulos EN100 Ethernet: en todas las versiones anteriores a V1.11.00; la variante de Firmware v TCP para los m\u00f3dulos EN100 Ethernet: en todas las versiones anteriores a V1.03; la variante de Firmware IEC 104 para los m\u00f3dulos EN100 Ethernet: en todas las versiones anteriores a V1.21 y el m\u00f3dulo EN100 Ethernet incluido en SIPROTEC Merging Unit 6MU80: todas las versiones anteriores a la 1.02.02; SIPROTEC 7SJ686: todas las versiones anteriores a la V 4.87 y SIPROTEC 7UT686: todas las versiones anteriores a la V 4.02 y SIPROTEC 7SD686: todas las versiones anteriores a la V 4.05 y SIPROTEC 7SJ66: todas las versiones anteriores a la V 4.30. Los atacantes que tengan acceso de red a la interfaz web del dispositivo (puerto 80/tcp) podr\u00edan omitir la autenticaci\u00f3n y realizar ciertas operaciones administrativas. Un usuario leg\u00edtimo debe tener la sesi\u00f3n iniciada en la interfaz web para que el ataque tenga \u00e9xito."
}
],
"metrics": {
"cvssMetricV30": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "3.0",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9
}
],
"cvssMetricV2": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"cvssData": {
"version": "2.0",
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"baseScore": 9.0,
"accessVector": "NETWORK",
"accessComplexity": "LOW",
"authentication": "SINGLE",
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"availabilityImpact": "COMPLETE"
},
"baseSeverity": "HIGH",
"exploitabilityScore": 8.0,
"impactScore": 10.0,
"acInsufInfo": false,
"obtainAllPrivilege": false,
"obtainUserPrivilege": false,
"obtainOtherPrivilege": false,
"userInteractionRequired": false
}
]
},
"weaknesses": [
{
"source": "nvd@nist.gov",
"type": "Primary",
"description": [
{
"lang": "en",
"value": "CWE-287"
}
]
}
],
"configurations": [
{
"operator": "AND",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:siemens:en100_ethernet_module_firmware:4.28:*:*:*:*:*:*:*",
"matchCriteriaId": "862476A4-6C97-4E00-9EC1-5EEA8A27EE73"
}
]
},
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": false,
"criteria": "cpe:2.3:h:siemens:en100_ethernet_module:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DAC429FD-7148-4A68-AA81-8FBADA588F4E"
}
]
}
]
}
],
"references": [
{
"url": "http://www.securityfocus.com/bid/92745",
"source": "cve@mitre.org"
},
{
"url": "http://www.securityfocus.com/bid/99471",
"source": "cve@mitre.org"
},
{
"url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-630413.pdf",
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
]
},
{
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03",
"source": "cve@mitre.org"
},
{
"url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf",
"source": "cve@mitre.org"
},
{
"url": "http://www.securityfocus.com/bid/92745",
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "http://www.securityfocus.com/bid/99471",
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-630413.pdf",
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
]
},
{
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03",
"source": "af854a3a-2127-422b-91ae-364da2661108"
},
{
"url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf",
"source": "af854a3a-2127-422b-91ae-364da2661108"
}
]
}