"id": "CVE-2023-20209",
|
|
"sourceIdentifier": "ykramarz@cisco.com",
|
|
"published": "2023-08-16T21:15:09.650",
|
|
"lastModified": "2023-08-24T14:23:42.837",
|
|
"vulnStatus": "Analyzed",
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "A vulnerability in the web-based management interface of Cisco Expressway Series and Cisco TelePresence Video Communication Server (VCS) could allow an authenticated, remote attacker with read-write privileges on the application to perform a command injection attack that could result in remote code execution on an affected device.\r\n\r This vulnerability is due to insufficient validation of user-supplied input. An attacker could exploit this vulnerability by sending a crafted request to the web-based management interface of an affected device. A successful exploit could allow the attacker to establish a remote shell with root privileges."
|
|
}
|
|
],
|
|
"metrics": {
|
|
"cvssMetricV31": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "HIGH",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "HIGH",
|
|
"baseScore": 7.2,
|
|
"baseSeverity": "HIGH"
|
|
},
|
|
"exploitabilityScore": 1.2,
|
|
"impactScore": 5.9
|
|
},
|
|
{
|
|
"source": "ykramarz@cisco.com",
|
|
"type": "Secondary",
|
|
"cvssData": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:N",
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "HIGH",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "NONE",
|
|
"baseScore": 6.5,
|
|
"baseSeverity": "MEDIUM"
|
|
},
|
|
"exploitabilityScore": 1.2,
|
|
"impactScore": 5.2
|
|
}
|
|
]
|
|
},
|
|
"weaknesses": [
|
|
{
|
|
"source": "nvd@nist.gov",
|
|
"type": "Primary",
|
|
"description": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-77"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"configurations": [
|
|
{
|
|
"nodes": [
|
|
{
|
|
"operator": "OR",
|
|
"negate": false,
|
|
"cpeMatch": [
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:cisco:telepresence_video_communication_server:*:*:*:*:*:*:*:*",
|
|
"versionEndExcluding": "14.3.1",
|
|
"matchCriteriaId": "0840F942-9484-461E-8F07-5691CD8E75DC"
|
|
},
|
|
{
|
|
"vulnerable": true,
|
|
"criteria": "cpe:2.3:a:cisco:telepresence_video_communication_server:*:*:*:*:expressway:*:*:*",
|
|
"versionEndExcluding": "14.3.1",
|
|
"matchCriteriaId": "B55E57CE-7762-418D-B85D-19EF29429623"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://sec.cloudapps.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-expressway-injection-X475EbTQ",
|
|
"source": "ykramarz@cisco.com",
|
|
"tags": [
|
|
"Vendor Advisory"
|
|
]
|
|
}
|
|
]
|
|
} |