2024-09-20 14:03:57 +00:00

64 lines
2.5 KiB
JSON

{
"id": "CVE-2024-8956",
"sourceIdentifier": "disclosure@vulncheck.com",
"published": "2024-09-17T20:15:07.287",
"lastModified": "2024-09-20T12:30:51.220",
"vulnStatus": "Awaiting Analysis",
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "PTZOptics PT30X-SDI/NDI-xx before firmware 6.3.40 is vulnerable to an insufficient authentication issue. The camera does not properly enforce authentication to /cgi-bin/param.cgi when requests are sent without an HTTP Authorization header. The result is a remote and unauthenticated attacker can leak sensitive data such as usernames, password hashes, and configurations details. Additionally, the attacker can update individual configuration values or overwrite the whole file."
},
{
"lang": "es",
"value": "Las c\u00e1maras PTZOptics PT30X-SDI/NDI-xx anteriores al firmware 6.3.40 son vulnerables a un problema de autenticaci\u00f3n insuficiente. La c\u00e1mara no aplica correctamente la autenticaci\u00f3n en /cgi-bin/param.cgi cuando se env\u00edan solicitudes sin un encabezado de autorizaci\u00f3n HTTP. El resultado es que un atacante remoto y no autenticado puede filtrar datos confidenciales, como nombres de usuario, hashes de contrase\u00f1as y detalles de configuraci\u00f3n. Adem\u00e1s, el atacante puede actualizar valores de configuraci\u00f3n individuales o sobrescribir todo el archivo."
}
],
"metrics": {
"cvssMetricV31": [
{
"source": "disclosure@vulncheck.com",
"type": "Secondary",
"cvssData": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "NONE",
"baseScore": 9.1,
"baseSeverity": "CRITICAL"
},
"exploitabilityScore": 3.9,
"impactScore": 5.2
}
]
},
"weaknesses": [
{
"source": "disclosure@vulncheck.com",
"type": "Secondary",
"description": [
{
"lang": "en",
"value": "CWE-287"
}
]
}
],
"references": [
{
"url": "https://ptzoptics.com/firmware-changelog/",
"source": "disclosure@vulncheck.com"
},
{
"url": "https://vulncheck.com/advisories/ptzoptics-insufficient-auth",
"source": "disclosure@vulncheck.com"
}
]
}